{"id":10937,"date":"2014-09-05T13:16:46","date_gmt":"2014-09-05T11:16:46","guid":{"rendered":"https:\/\/www.xyztec.com\/?p=10937"},"modified":"2023-09-19T11:21:30","modified_gmt":"2023-09-19T11:21:30","slug":"ideal-solution-for-300mm-12-inch-wafer-testing","status":"publish","type":"post","link":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/","title":{"rendered":"Ideal solution for 300mm (12 inch) wafer testing"},"content":{"rendered":"<h1>Sigma W12<\/h1>\n<p>The <a href=\"https:\/\/www.xyztec.com\/products\/sigma-w12\/\">Sigma W12<\/a> is based on xyztec&#8217;s market leading <a href=\"https:\/\/www.xyztec.com\/products\/sigma\/\">Sigma<\/a> platform. It shares many of the same features that set the\u00a0Sigma\u00a0apart from the rest of the industry. The\u00a0<a class=\"zwart\" href=\"https:\/\/www.xyztec.com\/products\/sigma-w12\/\">W12<\/a>\u2019s performance has been further enhanced for the precision and handling requirements of wafer testing.<\/p>\n<p><!--more--><\/p>\n<h2>Wafer testing up to 300mm<\/h2>\n<p>The\u00a0<a class=\"zwart\" href=\"https:\/\/www.xyztec.com\/products\/sigma-w12\/\">W12<\/a>\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure. The goal was to minimize downtime for companies that have multiple wafer diameters. Many test types are possible on the\u00a0<a class=\"zwart\" href=\"https:\/\/www.xyztec.com\/products\/sigma-w12\/\">Sigma W12<\/a>. The most common include solder ball shear and\u00a0<a href=\"https:\/\/www.xyztec.com\/knowledgecenter\/pull-tests\/cold-bump-pull-cbp\/\">Cold Bump Pull (CBP) testing<\/a>. Xyztec&#8217;s latest development is Pull Testing solder bumps on copper pillars. Xyztec also offers solutions for wire bonds on wafer. With the widest range of sensors and tooling there is something to suit almost any bond test application.<\/p>\n<h2><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-21396\" src=\"https:\/\/www.xyztec.com\/wp-content\/uploads\/Wafer-Pusher-Cleaner-web.png\" alt=\"Wafer-Pusher-Cleaner-web\" width=\"459\" height=\"339\" \/><\/h2>\n<h2><\/h2>\n<h2>Accurate fast full automation<\/h2>\n<p>All of xyztec&#8217;s axis movements are controlled with linear encoders. This technology provides unrivalled accuracy and it offers a significant improvement compared with rotary encoder solutions found on other equipment.<\/p>\n<div class=\"picture right\"><\/div>\n<p>Whether you are using the system in the manual or automatic mode, intelligent axis speed control of up to 50mm\/s enables the fastest traverse time over long distances. However, the\u00a0<a class=\"zwart\" href=\"https:\/\/www.xyztec.com\/products\/sigma-w12\/\">W12<\/a>\u00a0employs an automatic slow down feature as the tool approaches the target. This feature ensures precision and safety. Set up time is minimal. Wafer-map import capability provides accurate and rapid data transfer of the bonds to be tested. Other production functions include; onboard barcode reading and SPC data down load.<\/p>\n<p>&nbsp;<\/p>\n<h2>Automatic and manual Load\/Unload with warped wafer capability<\/h2>\n<p>The\u00a0Sigma W12\u00a0offers stand-alone manual loading or it can be fully integrated with wafer handlers (loader\/unloader). With the optional rotary table feature, wafer orientation can be accomplished quickly and accurately using manual or automatic functionality. A range of vacuum chucks and pin transfer options enable the handling of the most challenging of wafers.<\/p>\n<p>&nbsp;<\/p>\n<h2>Failure mode image capture<\/h2>\n<p>A range of\u00a0<a href=\"https:\/\/www.xyztec.com\/features\/automation\/smart-vision\/\">onboard camera options<\/a> enables high magnification images of the failure mode. These can be saved along with the test data either automatically or under operator control.<\/p>\n<div class=\"picture left\"><\/div>\n<h2>Debris collection<\/h2>\n<p>A debris collection option manages the debris resulting from test. Options include a programmable timed-pulse from an air jet to dislodge loose material from the test area, as well as a material vacuum pickup that captures loose material in a collection filter.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sigma W12 The Sigma W12 is bas [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":18369,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2969],"tags":[3618,3617,3417,3198,3622,3621,3619,3208,3620,3360],"class_list":["post-10937","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-newsletters","tag-12-inch","tag-300mm","tag-accurate","tag-automation","tag-debris-collection","tag-failure-mode-image-capture","tag-load-unload","tag-sigma-w12","tag-spc","tag-wafer-testing"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sigma W12; an ideal solution for 300mm (12&quot;) wafer testing<\/title>\n<meta name=\"description\" content=\"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sigma W12; an ideal solution for 300mm (12&quot;) wafer testing\" \/>\n<meta property=\"og:description\" content=\"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Xyztec\" \/>\n<meta property=\"article:published_time\" content=\"2014-09-05T11:16:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-09-19T11:21:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chantal\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chantal\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/\"},\"author\":{\"name\":\"Chantal\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/#\\\/schema\\\/person\\\/9090874e4977da4e1d9fcf8ed5fc6bc7\"},\"headline\":\"Ideal solution for 300mm (12 inch) wafer testing\",\"datePublished\":\"2014-09-05T11:16:46+00:00\",\"dateModified\":\"2023-09-19T11:21:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/\"},\"wordCount\":416,\"image\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.xyztec.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/Sigma-W12.jpg\",\"keywords\":[\"12 inch\",\"300mm\",\"accurate\",\"automation\",\"Debris collection\",\"Failure mode image capture\",\"Load\\\/unload\",\"Sigma W12\",\"SPC\",\"wafer testing\"],\"articleSection\":[\"Newsletters\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/\",\"url\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/\",\"name\":\"Sigma W12; an ideal solution for 300mm (12\\\") wafer testing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.xyztec.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/Sigma-W12.jpg\",\"datePublished\":\"2014-09-05T11:16:46+00:00\",\"dateModified\":\"2023-09-19T11:21:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/#\\\/schema\\\/person\\\/9090874e4977da4e1d9fcf8ed5fc6bc7\"},\"description\":\"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.xyztec.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/Sigma-W12.jpg\",\"contentUrl\":\"https:\\\/\\\/www.xyztec.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/Sigma-W12.jpg\",\"width\":600,\"height\":400,\"caption\":\"Sigma W12\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/ideal-solution-for-300mm-12-inch-wafer-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ideal solution for 300mm (12 inch) wafer testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/#website\",\"url\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/\",\"name\":\"Xyztec\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/#\\\/schema\\\/person\\\/9090874e4977da4e1d9fcf8ed5fc6bc7\",\"name\":\"Chantal\",\"url\":\"https:\\\/\\\/www.xyztec.com\\\/ja\\\/author\\\/chantal-chatrer\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sigma W12; an ideal solution for 300mm (12\") wafer testing","description":"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/","og_locale":"ja_JP","og_type":"article","og_title":"Sigma W12; an ideal solution for 300mm (12\") wafer testing","og_description":"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.","og_url":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/","og_site_name":"Xyztec","article_published_time":"2014-09-05T11:16:46+00:00","article_modified_time":"2023-09-19T11:21:30+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg","type":"image\/jpeg"}],"author":"Chantal","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"Chantal","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"2\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#article","isPartOf":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/"},"author":{"name":"Chantal","@id":"https:\/\/www.xyztec.com\/ja\/#\/schema\/person\/9090874e4977da4e1d9fcf8ed5fc6bc7"},"headline":"Ideal solution for 300mm (12 inch) wafer testing","datePublished":"2014-09-05T11:16:46+00:00","dateModified":"2023-09-19T11:21:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/"},"wordCount":416,"image":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg","keywords":["12 inch","300mm","accurate","automation","Debris collection","Failure mode image capture","Load\/unload","Sigma W12","SPC","wafer testing"],"articleSection":["Newsletters"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/","url":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/","name":"Sigma W12; an ideal solution for 300mm (12\") wafer testing","isPartOf":{"@id":"https:\/\/www.xyztec.com\/ja\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg","datePublished":"2014-09-05T11:16:46+00:00","dateModified":"2023-09-19T11:21:30+00:00","author":{"@id":"https:\/\/www.xyztec.com\/ja\/#\/schema\/person\/9090874e4977da4e1d9fcf8ed5fc6bc7"},"description":"The\u00a0W12\u00a0is designed to test any wafer size up to 300mm. Switching from various wafer sizes is a simple procedure.","breadcrumb":{"@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#primaryimage","url":"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg","contentUrl":"https:\/\/www.xyztec.com\/wp-content\/uploads\/2020\/08\/Sigma-W12.jpg","width":600,"height":400,"caption":"Sigma W12"},{"@type":"BreadcrumbList","@id":"https:\/\/www.xyztec.com\/ja\/ideal-solution-for-300mm-12-inch-wafer-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.xyztec.com\/ja\/"},{"@type":"ListItem","position":2,"name":"Ideal solution for 300mm (12 inch) wafer testing"}]},{"@type":"WebSite","@id":"https:\/\/www.xyztec.com\/ja\/#website","url":"https:\/\/www.xyztec.com\/ja\/","name":"Xyztec","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.xyztec.com\/ja\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/www.xyztec.com\/ja\/#\/schema\/person\/9090874e4977da4e1d9fcf8ed5fc6bc7","name":"Chantal","url":"https:\/\/www.xyztec.com\/ja\/author\/chantal-chatrer\/"}]}},"_links":{"self":[{"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/posts\/10937","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/comments?post=10937"}],"version-history":[{"count":1,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/posts\/10937\/revisions"}],"predecessor-version":[{"id":69808,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/posts\/10937\/revisions\/69808"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/media\/18369"}],"wp:attachment":[{"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/media?parent=10937"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/categories?post=10937"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.xyztec.com\/ja\/wp-json\/wp\/v2\/tags?post=10937"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}